Fehlerdiagnose-LED für Danfoss BD35 / BD50 kühlschrank
Fehler Diagnosekit für Auto Kühlschrank, Yacht, Wohnmobil mit Danfoss, Secop BD35, BD50 und Elektronikeinheit. Eine blinkende Leuchtdiode (LED) wird den Alarmcode schnell kommunizieren und den Servicetechniker auf das Problem hinweisen. Anzeige blinkt, Fehlerbehebung Selbstdiagnose.
Fault Diagnostic LED for Danfoss BD35/BD50
A 10mA light emitting diode (LED) can be connected between the terminals + and D.
In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash will last ¼ second. After the actual number of flashes there will be a delay with no flashes, so that the sequence for each error recording is repeated
every 4 seconds
Number Of flashes | Error type |
1 |
Battery protection cut-out (The voltage is outside the cut-out setting) |
2 |
Fan over-current cut-out (The fan loads the electronic unit with more than 1A peak). |
3 |
Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)). |
4 |
Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed 1,850 rpm). |
5 |
Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). |
Features:
- Cable length 1,5m